OH Consultant
← SWMS

Roof Work SWMS Templates

Roof access, trade-specific roofing, and roof safety infrastructure.

⚖️WHS Regulation 2025 & Codes of Practice — legally binding from 1 July 2026 (s26A)
👷Reviewed by certified occupational health and safety professionals
🗺️State-specific variants for all 8 Australian jurisdictions

About these SWMS

Roof Work SWMS templates cover safe systems of work for any task performed on, above, or accessing a roof — including roof installation, recladding, repairs, inspection, and the installation of fall protection infrastructure. Roof work is high risk construction work under WHS Regulation 2025 Part 6.3 whenever there is a risk of a fall of more than 2 metres, requiring a documented SWMS before work commences. Templates in this category align with the model Code of Practice: Managing the Risk of Falls at Workplaces, AS/NZS 1891 series for industrial fall-arrest systems, and AS/NZS 4994 for temporary edge protection. Suitable for roof plumbers, metal roofers, tilers, solar installers, and trades performing rooftop plant maintenance.

What this category covers

  • ✓Metal roof sheet installation, recladding, and removal
  • ✓Roof tile laying, replacement, and ridge capping
  • ✓Installation of roof safety mesh and anchor points
  • ✓Temporary edge protection erection and dismantling
  • ✓Roof penetrations for vents, flues, and skylights
  • ✓Box gutter and roof flashing installation and repair
  • ✓Solar panel mounting and rooftop PV installation
  • ✓Rooftop HVAC plant access, servicing, and replacement
  • ✓Roof inspection, leak detection, and condition assessment
  • ✓Asbestos cement roof sheet removal and replacement
  • ✓Roof anchor point recertification and load testing
  • ✓Translucent and fragile roof sheet replacement work
CIH-reviewed SWMS library

38 SWMS in this category

38 ready-to-buy editable DOCXs · 8 state variants per product · available for instant download.

🔍

Roofing

41 SWMS

Roofing Waterproofing

5 SWMS

Wah Solar Panel Install

5 SWMS

Wah Metal Roofing

3 SWMS

Wah Roof Ceiling Spaces

3 SWMS

Wah Roof Tiling

3 SWMS

Wah Roof Access General

1 SWMS

Wah Roof Cleaning

1 SWMS

Wah Roof Plumbing

1 SWMS

Wah Roof Repair

1 SWMS

Wah Roof Trusses

1 SWMS

Applicable standards & regulations

Model Code of Practice: Managing the Risk of Falls at Workplaces (Safe Work Australia)
Sets the hierarchy of fall controls PCBUs must apply when working at heights, including all roof access and roof-edge work.
WHS Regulation 2025 Part 6.3 — High Risk Construction Work (SWMS)
Requires a SWMS before commencing work where a person could fall more than 2 metres, which captures the majority of roof work.
AS/NZS 1891.1–1891.4 Industrial Fall-Arrest Systems and Devices
Specifies design, selection, use, and inspection of harnesses, lanyards, and anchorages used for roof access and fall arrest.
AS/NZS 4994.1 Temporary Edge Protection — General Requirements
Sets performance criteria for guardrails and edge protection installed around roof perimeters and penetrations during construction.

Frequently asked questions

Is roof work always classified as high risk construction work in Australia?

Roof work is classified as high risk construction work (HRCW) under WHS Regulation 2025 whenever there is a risk of a person falling more than 2 metres. This captures almost all pitched residential and commercial roof work. A SWMS must be prepared before work starts and reviewed if controls change. Even on low-set roofs under 2 metres, the model Code of Practice: Managing the Risk of Falls still requires risk assessment and control of fall hazards, fragile surfaces, and roof-edge work.

Do I need a separate SWMS for solar panel installation on a roof?

Yes — solar PV installation on roofs involves both working at heights HRCW and electrical HRCW once DC strings are connected. A combined SWMS should address fall protection per AS/NZS 1891, electrical isolation, panel handling, manual task risks, and roof penetration sealing. Many PCBUs maintain a dedicated rooftop solar SWMS separate from generic roof work documents because the electrical exposure and racking-specific hazards differ materially from standard roof plumbing or recladding tasks.

What fall protection is required when working on a metal roof in Australia?

The hierarchy of controls in the model Code of Practice: Managing the Risk of Falls requires elimination first, then passive controls like guardrails or scaffold to AS/NZS 4994.1, then work positioning systems, then fall-arrest systems to AS/NZS 1891. Roof safety mesh to AS/NZS 4389 may be used during installation. Travel restraint is preferred over fall arrest. Administrative controls and PPE alone are not acceptable as the sole control for roof-edge work.

Is a SWMS the same as a JSA for roof work?

No. A SWMS is a legally required document under WHS Regulation 2025 for high risk construction work, including roof work above 2 metres, and must identify hazards, controls, and how controls will be implemented, monitored, and reviewed. A JSA (Job Safety Analysis) is a general risk assessment tool with no specific legal status under the WHS Regulations. SWMS must be kept on site and accessible to the regulator; JSAs are an internal planning aid only.

Do roof work SWMS need to be customised for each state or territory?

The model WHS Regulations are harmonised across most Australian jurisdictions, so a well-drafted roof work SWMS aligned with WHS Regulation 2025 and the model Code of Practice: Managing the Risk of Falls is broadly applicable. However, Victoria operates under the OHS Act 2004 and Regulations 2017, and Western Australia has its own WHS Act 2020 with specific provisions. Site-specific customisation — addressing the actual roof type, pitch, height, and access — is required regardless of jurisdiction.

Roof Work SWMS

Editable DOCX templates, 8 state variants per product, CIH-reviewed.

Browse all SWMS