Demountable partition installation involves erecting proprietary framed panel systems β typically aluminium or steel head/floor tracks, vertical studs, and infill panels of MDF, glazed units or acoustic laminates β to divide commercial tenancies, retail fitouts and office floorplates. Work commonly occurs at height from mobile scaffolds, step platforms or elevating work platforms to fix top tracks to concrete slabs or suspended ceilings, and involves rotary hammer drilling, powder-actuated fasteners, glazing lifts, and integration with live electrical, data and HVAC services. The hazards are compounded by fitout programme pressure, shared occupation with other trades, and the concealed nature of ceiling voids and existing wall linings that may contain crystalline silica dust or asbestos-containing materials.
Under the Work Health and Safety Regulation 2025 (NSW), work carried out at a height where there is a risk of a person falling more than 2 metres is high risk construction work under section 291(a). Section 299 requires a Safe Work Method Statement to be prepared before the work commences, kept available for inspection, and complied with. Controls must follow the hierarchy in section 36, and the SWMS must be developed in consultation with workers under section 47 and reviewed under section 302 whenever controls are revised or an incident occurs.
Hazards identified
12 hazards covered, sorted by priority.
Fatal or catastrophic head, spinal and internal injuries from fall to hard floor
Mesothelioma, asbestosis and lung cancer from inhalation of respirable asbestos fibres
Silicosis, lung cancer and chronic obstructive pulmonary disease from RCS exposure above the 0.05 mg/mΒ³ WES
Electrocution, arc flash burns or serious water damage escalation
Penetrating projectile injury, eye loss or fatality to operator or bystander
Acute lumbar disc injury, crush injuries to hands and feet, chronic musculoskeletal disorder
Deep lacerations, tendon damage and blood loss from broken glazing edges
Head and shoulder injuries, concussion
Noise-induced hearing loss exceeding the 85 dB(A) eight-hour exposure standard
Fractures, sprains, lacerations from fall onto sharp offcuts
Corneal abrasion, chemical conjunctivitis, permanent vision impairment
Elevated risk of falls, tool errors and cognitive lapses
Control measures
Hierarchy-of-controls order: elimination β substitution β isolation β engineering β administrative β PPE.
- 1Eliminate work at height where practicable by pre-assembling partition modules at ground level and using proprietary systems designed for floor-level jointing before lifting into position.
- 2Substitute powder-actuated fasteners with mechanical anchors or drilled expansion fixings where slab conditions permit, reducing projectile and noise hazards.
- 3Before any penetration, obtain a current asbestos register under section 425 and, for pre-2004 buildings without a register, arrange a licensed hygienist inspection; suspected ACM triggers Class A/B removal to AS 2601 and the SafeWork NSW Code of Practice: How to Safely Remove Asbestos.
- 4Control respirable crystalline silica by using on-tool H-class HEPA dust extraction and water suppression on all drilling and cutting, in accordance with the SafeWork NSW Code of Practice: Managing the Risks of Respirable Crystalline Silica from Engineered Stone in the Workplace and general RCS guidance; air monitoring where the WES may be exceeded.
- 5Engineer fall protection: use compliant mobile scaffolds to AS/NZS 1576 with guardrails on all sides, or EWPs operated by yellow-card holders to AS 2550.10; prohibit use of A-frame ladders for track fixing above 2 m.
- 6Isolate and lock out electrical circuits in the work zone under AS/NZS 4836 before any wall or ceiling penetration; verify de-energisation with a tested voltage indicator and cable-locate services with a CAT/genny scanner before drilling.
- 7PAT operation restricted to workers holding current manufacturer certification; tools stored, maintained and used to AS/NZS 1873; establish a 3 m exclusion zone with signage and physical barriers, and never fire into occupied adjoining tenancies.
- 8Two-person lift or mechanical aid (panel trolley, glazing robot, suction lifter to AS/NZS 4991) mandatory for panels over 25 kg or full-height glazed leaves; edge protection gloves and safety footwear worn at all times.
- 9Housekeeping regime: continuous removal of offcuts and packaging, delineated material laydown areas, and tool tethering when working from platforms above other trades.
- 10PPE baseline: safety helmet to AS/NZS 1801, medium-impact eye protection to AS/NZS 1337.1, P2 respiratory protection (or PAPR for prolonged silica work) to AS/NZS 1716 fit-tested per AS/NZS 1715, Class 5 hearing protection to AS/NZS 1270, cut-resistant gloves and safety footwear to AS/NZS 2210.3.
- 11All workers hold a current General Construction Induction Card (CPCCWHS1001 β White Card); the SWMS is developed in consultation with workers under section 47 of the WHS Act, signed by each worker before starting, and reviewed under section 302 whenever controls change, an incident occurs, or a new hazard is identified.
Applicable Codes of Practice
Primary code for fall prevention above 2 m during top-track and ceiling fixing; establishes the hierarchy from elimination through fall-arrest systems.
Sets SWMS content, consultation and review requirements for HRCW under section 299, and general construction site duties.
Applies whenever penetrating or altering existing wall, floor or ceiling linings in pre-2004 commercial buildings.
Specifies design, erection and use of mobile scaffolds commonly used for partition installation.
High-Risk Construction Work triggered
Fixing head tracks, cornices and full-height panels to slabs and ceiling grids in commercial fitouts routinely requires work from mobile scaffolds, platform ladders or EWPs at working heights exceeding 2 metres above the finished floor, meeting the section 291(a) threshold.
Because the work is high risk construction work, section 299 of the Work Health and Safety Regulation 2025 (NSW) requires a SWMS to be prepared before work starts, complied with during the work, and kept available for inspection; section 302 requires review whenever controls are revised or an incident occurs. Failure to prepare, comply with or produce a SWMS is an offence attracting penalties under the Work Health and Safety Act 2011 (NSW). More serious breaches causing exposure to death or serious injury may be prosecuted as Category 2 offences under section 32, or Category 1 offences under section 31 where recklessness is established. Current maximum penalties are published in the SafeWork NSW penalty schedule.
Who this is for
- βShopfitting and commercial fitout contractors installing demountable partition systems
- βJoiners and carpenters transitioning into commercial partition work
- βPrincipal contractors coordinating multi-trade tenancy fitouts
- βSite supervisors preparing HRCW documentation for shopping centre and CBD projects
- βSole-trader shopfitters tendering for corporate and retail fitout packages
What you receive
- βEditable Microsoft Word SWMS pre-populated for demountable partition installation in NSW
- βFull section 291(a) HRCW justification and section 299 compliance mapping
- βHazard and risk register with pre- and post-control risk ratings
- βHierarchy-of-control matrix aligned to section 36 of the WHS Regulation 2025 (NSW)
- βWorker consultation and sign-on register meeting section 47 requirements
- βPlant, tool and PPE schedule referencing current AS/NZS standards
- βEmergency response and incident notification procedure referencing section 38 of the WHS Act
- βSWMS review and amendment log to satisfy section 302
- βAustralian-based email support for one document revision within 30 days of purchase
Worked example
A shopfitting subcontractor in Parramatta is engaged to install 180 linear metres of demountable glazed partitioning across Level 14 of a commercial tower, converting open-plan floorplate into meeting rooms. Top tracks fix to the underside of a 3.1 m concrete soffit, requiring drilled anchors from a mobile scaffold. The building predates 2004, so an asbestos register review is completed and a licensed hygienist confirms the soffit is clear. Rotary hammer drilling is performed with H-class on-tool extraction to control silica dust, and circuits in the ceiling void are isolated and locked out under AS/NZS 4836 before penetration. Full-height 55 kg glazed leaves are moved with a suction lifter, and a two-person lift protocol applies. The SWMS is signed by each of the four installers at the pre-start, reviewed after a near-miss involving a dropped offcut on day three, and produced on request during a SafeWork NSW inspector visit.
Related legislation
- Work Health and Safety Act 2011 (NSW) β primary duties (sections 19, 31, 32) and consultation (section 47)
- Work Health and Safety Regulation 2025 (NSW) β HRCW (section 291), SWMS (sections 299-302), falls (section 79), hazardous chemicals, and asbestos (Chapter 8)
- Environmental Planning and Assessment Act 1979 (NSW) β for fitout approvals and Class 5/6 building compliance
- Building and Construction Industry Security of Payment Act 1999 (NSW) β contractual context for subcontracted fitout work
- Protection of the Environment Operations Act 1997 (NSW) β construction waste and dust management obligations
- Electricity Supply (Safety and Network Management) Regulation 2024 (NSW) β where work interfaces with electrical installations
Frequently asked questions
Is a SWMS legally required for every demountable partition job in NSW?
A SWMS is only mandatory where the work meets the definition of high risk construction work under section 291 of the WHS Regulation 2025 (NSW). Most commercial partition installations trigger section 291(a) because head-track fixing occurs above 2 metres. Where all work is genuinely below 2 metres and no other HRCW category applies, a SWMS is not legally required, but a documented risk assessment is still expected under section 19 of the WHS Act.
Do I need a licensed asbestos assessor before penetrating existing walls?
For buildings constructed or refurbished before 31 December 2003, the person conducting the business or undertaking who manages the workplace must maintain an asbestos register under section 425 of the WHS Regulation 2025 (NSW). If no register exists or the material is unidentified, arrange a licensed asbestos assessor inspection before any drilling, cutting or demolition. Suspected ACM must not be disturbed until sampled.
Can I use an A-frame ladder to fix the top track instead of a scaffold?
Ladders are the lowest-order fall control and are not appropriate for two-handed drilling and fixing work above 2 metres. SafeWork NSW guidance and the Code of Practice: Managing the Risk of Falls at Workplaces require higher-order controls such as mobile scaffolds to AS/NZS 1576 or EWPs to AS 2550.10 for this task. Ladder use should be limited to short-duration, light-force tasks only.
Who needs to sign the SWMS?
Every worker performing the demountable partition work must be consulted during SWMS development (section 47 of the WHS Act) and sign the document before starting on site to confirm they understand the controls. The SWMS must be kept accessible on site for the duration of the work and for at least two years after any notifiable incident, and must be produced on request by a SafeWork NSW inspector.
Document details
Related SWMS templates
πͺGlass Partition Installation SWMS
NSW β Glass Partition Installation. Full task scope, hazards and controls to be authored to Phase 1 standard.
π§±Acoustic Ceiling Tile Installation SWMS
NSW β Acoustic Ceiling Tile Installation. Full task scope, hazards and controls to be authored to Phase 1 stanβ¦
π’Aluminium Composite Panel Installation SWMS
NSW β Aluminium Composite Panel Installation. Full task scope, hazards and controls to be authored to Phase 1 β¦
π§Artificial Turf Installation SWMS
NSW β Artificial Turf Installation. Full task scope, hazards and controls to be authored to Phase 1 standard.
πBoiler & Pressure Vessel Installation SWMS
NSW β Boiler & Pressure Vessel Installation. Full task scope, hazards and controls to be authored to Phase 1 sβ¦
π‘οΈBoiler Installation & Commissioning SWMS
NSW β Boiler Installation & Commissioning. Full task scope, hazards and controls to be authored to Phase 1 staβ¦