Furnace and heating installation covers the delivery, positioning, connection and commissioning of gas-fired furnaces, ducted heating units, hydronic boilers and associated flue, gas and electrical services in residential, commercial and industrial settings. The work commonly involves manual handling of heavy plant into confined roof spaces, sub-floors and plant rooms, connecting to live or newly charged gas piping, brazing and hot-work on copper lines, cutting or drilling through building fabric that may contain asbestos or crystalline silica, and commissioning combustion equipment where CO, LPG or natural gas leaks, hot surfaces and pressurised flues create acute exposure risk.
Under the Work Health and Safety Regulation 2025 (NSW), section 291 classifies work in or near a confined space (f), work on or near pressurised gas distribution mains or piping (i), and work in artificial extremes of temperature (p) as high risk construction work. Section 299 requires a Safe Work Method Statement to be prepared before that work commences, and section 302 requires it to be reviewed and revised where controls are inadequate. Controls are selected under the hierarchy in section 36, supported by gas licensing under the Gas and Electricity (Consumer Safety) Act 2017 (NSW).
Hazards identified
12 hazards covered, sorted by priority.
Explosion, flash fire, fatal burns and structural damage
Acute CO poisoning, unconsciousness, fatality
Asphyxiation, collapse, delayed rescue fatality
Full-thickness burns, heat stress, dehydration collapse
Structural fire, LPG cylinder BLEVE, burns
Airborne fibre release; mesothelioma, asbestosis
Silicosis, accelerated fibrotic lung disease
Crush injuries, chronic musculoskeletal disorders
Electrocution, arc flash burns
Fatal fall, spinal injury
Scalding, steam burns, projectile fittings
Noise-induced hearing loss
Control measures
Hierarchy-of-controls order: elimination β substitution β isolation β engineering β administrative β PPE.
- 1Eliminate confined space entry where possible by pre-assembling manifolds, flue sections and control panels outside the space and craning modules into position on skids.
- 2Substitute oxy-acetylene brazing with press-fit or mechanical gas fittings certified to AS 4041 and AS/NZS 5601.1 where the appliance manufacturer permits, reducing hot work ignition risk.
- 3Engineer gas isolation by fitting lockable emergency shut-off valves upstream of the work area, purging piping with inert gas to AS/NZS 5601.1 before disconnection, and pressure-testing with soapy water or electronic gas detector before recommissioning.
- 4Engineer confined space safety through mechanical ventilation, continuous 4-gas atmospheric monitoring (O2, LEL, CO, H2S) to AS/NZS 2865, permit-to-work, tripod retrieval and a trained standby person outside the space.
- 5Engineer hot-work fire controls: 1.5 m radius clearance, non-combustible screens, charged fire extinguisher (9 L water and CO2), and a documented 60-minute fire watch to AS 1674.1 after brazing.
- 6Control silica dust at flue penetrations using tool-integrated water suppression or on-tool H-class extraction to comply with the section-26A Code of Practice: Managing the risks of respirable crystalline silica from engineered stone in the workplace and general silica duty under Regulation 2025 sections 49-50.
- 7Assume asbestos presence in pre-2004 plant lagging; require a licensed asbestos assessor report before disturbance and engage a Class B (or Class A for friable) licensed removalist under Regulation 2025 Chapter 8.
- 8Administrative: only Certificate III qualified Type A gas fitters holding a current NSW gas fitting licence issued under the Gas and Electricity (Consumer Safety) Act 2017 (NSW) perform gas work; electrical work by licensed electricians under the Home Building Act 1989 (NSW).
- 9Administrative: heat management through work-rest cycles per the section-26A Code of Practice: Managing the risks of heat in the workplace, cool water access, and locking out and cooling combustion equipment before internal work.
- 10PPE: FR-rated coveralls (AS/NZS 4824), P2 respirator (AS/NZS 1716) or PAPR for asbestos/silica tasks, heat-resistant gauntlets, safety glasses to AS/NZS 1337, and hearing protection to AS/NZS 1270.
- 11Fall protection: edge protection, harness anchored to a certified point per AS/NZS 1891 series when installing rooftop flues, and covers or crawl boards over fragile ceilings.
- 12All workers hold CPCCWHS1001 (White Card); the SWMS is consulted on with workers under section 47 of the WHS Act 2011 (NSW), signed prior to work, and reviewed under section 302 of the Regulation 2025 whenever controls change, an incident occurs, or a new hazard is identified.
Applicable Codes of Practice
Governs risk assessment, entry permits, atmospheric testing and rescue arrangements for entry into plant rooms, roof cavities and boiler enclosures.
Applies to storage, use and connection of natural gas, LPG, brazing fluxes and combustion by-products encountered during heating installation.
Technical standard for design, installation, purging and commissioning of gas piping and appliances up to 200 kPa.
Governs electrical connection, earthing and RCD protection of furnace controls, ignition circuits and combustion fans.
High-Risk Construction Work triggered
Installers routinely enter roof spaces, sub-floors, boiler enclosures and plant pits meeting the AS/NZS 2865 confined space definition, with limited egress and potential for oxygen deficiency, CO or unburnt gas accumulation.
Connection, disconnection and commissioning of appliances involves working directly on pressurised natural gas and LPG piping downstream of the meter or bulk regulator.
Commissioning and servicing occurs adjacent to operating furnaces, boilers and flues where surface and radiant temperatures exceed normal workplace thermal ranges.
Section 299 of the WHS Regulation 2025 (NSW) requires a SWMS to be prepared before this work starts and section 302 requires review whenever controls change or an incident occurs. Failure to prepare, comply with or produce a SWMS is a strict-liability offence. Where non-compliance exposes a worker to risk of death or serious injury, prosecution may proceed under sections 31 (Category 1 - reckless conduct) or 32 (Category 2) of the Work Health and Safety Act 2011 (NSW). Current maximum penalties are published on the SafeWork NSW penalties and notices register and are indexed annually.
Who this is for
- βLicensed Type A gas fitters and plumbing contractors installing residential and commercial heating
- βHVAC principal contractors managing mechanical services fit-outs
- βHydronic heating specialists commissioning boilers and radiator circuits
- βFacilities and maintenance managers overseeing furnace replacement in existing plant rooms
- βWHS advisors preparing pre-start documentation for gas and combustion works
What you receive
- βEditable Word SWMS pre-populated for NSW furnace and heating installation
- βSection 291(f), (i) and (p) HRCW justification block with legal citations
- βTask-based Job Step Analysis covering delivery, positioning, gas, electrical, flue and commissioning stages
- βRisk matrix aligned to ISO 31000 with pre- and post-control ratings
- βConsultation and sign-on register meeting section 47 of the WHS Act 2011 (NSW)
- βConfined space entry permit and atmospheric monitoring log
- βHot work permit and fire watch record aligned to AS 1674.1
- βGas purging, pressure test and commissioning checklist referencing AS/NZS 5601.1
- βSWMS review and revision log satisfying section 302 of the WHS Regulation 2025 (NSW)
Worked example
A mechanical services contractor is replacing a 250 kW natural-gas fired boiler in the basement plant room of a commercial building in Parramatta. The existing boiler is a 1998 unit with suspected asbestos-containing rope gaskets and millboard behind the burner plate. Access is via a single doorway; the plant room is classified as a confined space under AS/NZS 2865. The SWMS documents pre-entry atmospheric testing, mechanical purge ventilation, licensed Class B asbestos removal of gaskets before decommissioning, isolation and lockout of the 100 kPa gas supply at the meter with a nitrogen purge to AS/NZS 5601.1, a hot work permit for silver-brazing the new copper header, and a fire watch. Two Type A gas fitters and a licensed electrician are consulted under section 47 and sign on before work. Following a minor CO alarm during commissioning, the SWMS is reviewed under section 302, flue draft is recalibrated, and continuous CO monitoring is added for the remaining commissioning phase.
Related legislation
- Work Health and Safety Act 2011 (NSW)
- Work Health and Safety Regulation 2025 (NSW)
- Gas and Electricity (Consumer Safety) Act 2017 (NSW)
- Gas Supply Act 1996 (NSW)
- Electricity (Consumer Safety) Act 2004 (NSW)
- Protection of the Environment Operations Act 1997 (NSW)
Frequently asked questions
Does every furnace installation need a SWMS, or only large commercial jobs?
Any furnace or heating installation that involves work on pressurised gas piping, entry to a confined space (including many roof cavities and plant rooms) or work in artificial extremes of temperature triggers section 291 of the WHS Regulation 2025 (NSW). A SWMS is mandatory before that work starts regardless of the size of the appliance or contract value.
Who can legally perform the gas connection component?
In NSW, gas fitting work must be performed by a person holding a current gas fitting licence issued under the Gas and Electricity (Consumer Safety) Act 2017 (NSW). Typically this requires Certificate III in Plumbing with a Type A gas appliance endorsement. The SWMS records the licence numbers of workers performing gas work.
How do we manage asbestos found in an existing boiler during replacement?
Stop work immediately. Under Chapter 8 of the WHS Regulation 2025 (NSW), a licensed asbestos assessor must sample and identify the material, and a Class B (bonded) or Class A (friable) licensed removalist must remove it before installation continues. The SWMS is revised under section 302 to reflect the new controls.
Is CO monitoring required during commissioning?
Yes. Combustion appliances can produce carbon monoxide during initial firing, particularly if flue draft is incorrect. Continuous personal or area CO monitoring during commissioning is a standard control in this SWMS, aligned with the confined spaces and hazardous chemicals Codes of Practice approved under section 274 of the WHS Act 2011 (NSW).
Document details
Related SWMS templates
π§±Acoustic Ceiling Tile Installation SWMS
NSW β Acoustic Ceiling Tile Installation. Full task scope, hazards and controls to be authored to Phase 1 stanβ¦
π’Aluminium Composite Panel Installation SWMS
NSW β Aluminium Composite Panel Installation. Full task scope, hazards and controls to be authored to Phase 1 β¦
π§Artificial Turf Installation SWMS
NSW β Artificial Turf Installation. Full task scope, hazards and controls to be authored to Phase 1 standard.
πBoiler & Pressure Vessel Installation SWMS
NSW β Boiler & Pressure Vessel Installation. Full task scope, hazards and controls to be authored to Phase 1 sβ¦
π‘οΈBoiler Installation & Commissioning SWMS
NSW β Boiler Installation & Commissioning. Full task scope, hazards and controls to be authored to Phase 1 staβ¦
π§Box Culvert Installation SWMS
NSW β Box Culvert Installation. Full task scope, hazards and controls to be authored to Phase 1 standard.