Chimney & Fireplace Masonry SWMS
NSW β Chimney & Fireplace Masonry. Full task scope, hazards and controls to be authored to Phase 1 standard.
SWMS variants reference your stateβs WHS legislation. Instant download after payment.
Chimney and fireplace masonry involves constructing, rebuilding, repointing or demolishing brick or stone chimneys, flues and fireboxes, typically on pitched roofs or within occupied dwellings. The work combines exposure to falls from height at ridge level, manual handling of heavy masonry units and lintels, hot-work when installing flue liners, and disturbance of existing structures that may contain lead-based paint, asbestos cement flue components or crystalline silica in mortar and firebrick. Partial demolition of a chimney stack above roof line frequently requires temporary propping of the remaining structure and load transfer through the roof framing, creating a real risk of collapse if sequencing is wrong.
Under the Work Health and Safety Regulation 2025 (NSW), this work is high risk construction work under section 291 β specifically falls greater than 2 metres (291(a)) and structural alteration requiring temporary support (291(e)). Section 299 therefore requires a Safe Work Method Statement to be prepared before work commences, kept available for inspection, and complied with. Controls follow the hierarchy in section 36: eliminate work at height where practicable via scaffolds and edge protection, engineer temporary support before disturbing load paths, and use administrative and PPE controls to manage residual silica, dust and manual handling risks.
Hazards identified
12 hazards covered, sorted by priority.
Fatal or catastrophic injury from fall to ground or lower level
Crush injury or fatality to workers or occupants below
Head injury, fractures, fatality
Silicosis, lung cancer, chronic obstructive pulmonary disease
Mesothelioma, asbestosis, lung cancer
Chronic musculoskeletal injury, acute back and shoulder injury
Fall through roof, serious injury or fatality
Burns, structure fire, delayed combustion in roof void
Lead poisoning, neurological and reproductive harm
Electrocution, arc flash burns
Slip, loss of balance, heat illness, hypothermia
Acute CO poisoning, respiratory irritation
Control measures
Hierarchy-of-controls order: elimination β substitution β isolation β engineering β administrative β PPE.
- 1Eliminate work at height where practicable by prefabricating flue and cap assemblies at ground level and lifting into position with a crane or telehandler.
- 2Substitute mechanical cutting with wet-cut masonry saws and diamond core drilling with integrated water suppression to eliminate dry cutting of silica-containing materials.
- 3Erect a compliant perimeter scaffold to AS/NZS 1576 series and AS/NZS 4576 with a working platform within 300 mm of the chimney and edge protection to all open sides before roof access commences.
- 4Engineer temporary support for partial chimney demolition or lintel replacement using acrow props, needle beams or engineer-designed propping; retain a structural engineer's certificate for section 291(e) alteration work.
- 5Before disturbing any pre-1990 chimney fabric, obtain an asbestos register or arrange sampling under the How to Manage and Control Asbestos in the Workplace Code of Practice; licensed removal per section 458 if ACM is confirmed.
- 6Implement on-tool water suppression or H-class M-class LEV extraction on all grinders, saws and chasers per the Working with Silica and Silica Containing Products Code of Practice; air monitoring where the workplace exposure standard may be exceeded.
- 7Establish a ground exclusion zone with hard barricades and signage below the work area; use enclosed rubbish chutes or lowered kibbles rather than throwing debris.
- 8Roof access via ladder complying with AS/NZS 1892.1 secured top and bottom, or via internal manhole with fall protection; roof anchors installed to AS/NZS 5532 where a harness system is used as a last resort.
- 9Hot work permit system with fire watch for 60 minutes post-work, dry-chemical extinguisher on the platform, and combustibles removed or covered with fire blankets within 3 m of the ignition source.
- 10Manual handling controls β mechanical hoist or wheel-barrow-mounted brick elevator to roof platform, two-person lifts for lintels over 20 kg, and job rotation to limit sustained overhead work.
- 11Minimum P2 respirators for silica tasks (upgraded to PAPR for extended cutting), Tyvek coveralls, cut-resistant gloves, safety glasses to AS/NZS 1337.1, hard hat to AS/NZS 1801 and Type 3 fall arrest harness to AS/NZS 1891.1 where used.
- 12All workers hold CPCCWHS1001 (White Card); SWMS consulted with workers under section 47 of the WHS Act, signed before work starts, and reviewed under section 302 whenever controls change, an incident occurs, or the work method is varied.
Applicable Codes of Practice
Primary code for fall prevention on pitched roofs and chimney stacks above 2 m.
SWMS content, HRCW controls and general construction duties under section 291 and 299.
Control of respirable crystalline silica from brick, mortar and firebrick cutting.
Identification and management of asbestos in older chimney flues and flashings.
High-Risk Construction Work triggered
Chimney masonry is performed at or above the roof ridge, routinely 3-8 m above ground level, with unprotected edges on all sides of the stack.
Partial demolition and rebuild of a chimney above roof line, replacement of fireplace lintels, and opening up of hearths transfer load paths and require acrow props, needle beams or engineered propping to prevent collapse of the remaining structure.
Section 299 of the WHS Regulation 2025 (NSW) requires a SWMS to be prepared before HRCW starts, complied with, and kept accessible. Section 302 requires review whenever controls are inadequate, work methods change or after an incident. Failure to prepare or comply exposes the PCBU to enforcement including improvement and prohibition notices, and prosecution under the WHS Act 2011 (NSW) as a Category 2 offence under section 32 or, where reckless conduct causes exposure to death or serious injury, a Category 1 offence under section 31. Current penalty amounts are set out in the SafeWork NSW penalty schedule and are indexed periodically.
Who this is for
- βBricklaying and stonemasonry contractors performing chimney construction, repair or demolition
- βHeritage restoration builders working on Federation and Victorian-era dwellings
- βRoof plumbers and flue installers integrating masonry chimneys with metal flashings
- βDomestic builders and renovation contractors opening fireplaces or replacing hearths
- βPrincipal contractors coordinating trades on residential renovation sites in NSW
What you receive
- βEditable Word (.docx) SWMS pre-populated for chimney and fireplace masonry
- βPDF reference copy formatted for site display and toolbox use
- βHRCW declaration section pre-completed for section 291(a) and 291(e)
- βHazard and control register aligned to the NSW hierarchy of control
- βWorker consultation and sign-on register meeting section 47 of the WHS Act
- βSWMS review log for section 302 amendments
- βEmergency response and rescue-from-height plan template
- βSilica and asbestos risk annex referencing the current NSW Codes of Practice
- βFree lifetime updates when NSW WHS Regulation or Codes change
Worked example
A bricklaying subcontractor in Katoomba is engaged to demolish the upper 1.8 m of a deteriorated chimney stack on a two-storey 1920s weatherboard cottage and rebuild it in matching recycled brick with a new stainless flue liner. Roof height at the stack is 6.4 m. Because the work involves both a fall risk greater than 2 m (section 291(a)) and structural alteration requiring temporary propping of the remaining stack and roof penetration (section 291(e)), a SWMS is prepared and signed by all workers before mobilisation. A modular scaffold with a working platform 400 mm below the chimney cap is erected, an asbestos inspection confirms the original cement flue liner is chrysotile-containing and is removed by a Class B licensed removalist, and brick cutting is performed on a ground-level wet saw. The SWMS is reviewed on day three when weather forces a change to internal hearth works, satisfying section 302.
Related legislation
- Work Health and Safety Act 2011 (NSW)
- Work Health and Safety Regulation 2025 (NSW)
- Protection of the Environment Operations Act 1997 (NSW) β construction and demolition waste
- Environmental Planning and Assessment Act 1979 (NSW) β heritage and complying development
- Dangerous Goods (Road and Rail Transport) Act 2008 (NSW) β asbestos and hazardous waste transport
- Heritage Act 1977 (NSW) β where the dwelling is on the State Heritage Register
Frequently asked questions
Is a SWMS required if the chimney is only 1.9 m above the roof but the roof itself is 5 m off the ground?
Yes. Section 291(a) measures the potential fall distance to the surface a worker could land on, not the height of the object being worked on. A fall from the roof to ground exceeds 2 m, so the work is HRCW and a SWMS is mandatory under section 299 of the WHS Regulation 2025 (NSW).
Do I need an engineer for temporary propping when rebuilding a chimney above the roof line?
If removing the upper section could destabilise the remaining stack, hearth or roof framing, engineered propping is required under section 299(e). For simple cap or corbel replacements where the load path is not disturbed, proprietary acrow props installed to manufacturer's specifications may suffice β the SWMS must document the basis for the decision.
How do we handle old cement flue liners that might contain asbestos?
Do not disturb suspect material until it is sampled by a competent person or assumed to be asbestos. Chrysotile cement flues are common in dwellings built before 1990. Friable material or more than 10 mΒ² of non-friable ACM must be removed by a licensed asbestos removalist under sections 458-459 of the WHS Regulation 2025 (NSW).
Can this SWMS be used across multiple sites?
The document is a template that must be tailored to each site's specific hazards β roof pitch, access, adjacent structures, occupancy, and the age of the chimney fabric. Section 47 of the WHS Act requires consultation with the workers actually performing the task, and section 302 requires review whenever site conditions or the work method change.
Document details
Related SWMS templates
π§±Masonry Cleaning & Caulking SWMS
NSW β Masonry Cleaning & Caulking. Full task scope, hazards and controls to be authored to Phase 1 standard.
π§±Stonework - Masonry SWMS
NSW β Stonework - Masonry. Full task scope, hazards and controls to be authored to Phase 1 standard.
π§±Acoustic Ceiling Tile Installation SWMS
NSW β Acoustic Ceiling Tile Installation. Full task scope, hazards and controls to be authored to Phase 1 stanβ¦
π’Aluminium Composite Panel Installation SWMS
NSW β Aluminium Composite Panel Installation. Full task scope, hazards and controls to be authored to Phase 1 β¦
π§Artificial Turf Installation SWMS
NSW β Artificial Turf Installation. Full task scope, hazards and controls to be authored to Phase 1 standard.
β£οΈAsbestos Soil Remediation SWMS
NSW β Asbestos Soil Remediation. Full task scope, hazards and controls to be authored to Phase 1 standard.