Cadmium Work SWMS: Controlling Exposure Under the New 2026 Workplace Exposure Limit
Cadmium is a heavy metal classified by the International Agency for Research on Cancer (IARC) as a Group 1 carcinogen — it is a confirmed cause of lung cancer in humans, and chronic exposure causes irreversible kidney disease (Itai-itai disease) and bone demineralisation. On 1 December 2026, Safe Work Australia will reduce the workplace exposure limit (WEL) for cadmium (as Cd, inhalable fraction) from 0.010 mg/m³ to 0.001 mg/m³ — a 90 per cent reduction. This is the largest single downward revision to a WEL in Australian occupational health history and will require significant upgrades to engineering controls and health monitoring programmes across all industries where cadmium exposure can occur.
SWMS variants reference your state’s WHS legislation. Instant download after payment.
Legal Requirements
WHS Regulations 2017, Part 7.1 (Hazardous Chemicals), regulations 356–383 (Health monitoring); Workplace Exposure Standards for Airborne Contaminants (SWA, amended effective 1 December 2026): cadmium (as Cd, inhalable) TWA 0.001 mg/m³
Category 10 — Work involving hazardous material or a contaminated area (WHS Regulation r291(1)(j)); cadmium compounds are Schedule 10 hazardous chemicals with mandatory health surveillance under r356
Model Code of Practice: Managing Risks of Hazardous Chemicals in the Workplace (SWA 2021); Model Code of Practice: Welding Processes (SWA 2020); Guidance: Work Health and Safety Management of Cadmium in the Workplace (SWA)
true
Hazards
| Hazard | Consequence | Likelihood |
|---|---|---|
| Inhalation of cadmium fume during welding, cutting, or heating of cadmium-coated or cadmium-containing metals | Cadmium oxide fume generated during welding or thermal cutting of cadmium-plated components is inhaled directly into the deep lung. | Almost Certain (A) without effective LEV |
| Inhalation of cadmium mist and fume from hard chrome/cadmium electroplating baths | Cadmium electroplating baths generate a fine aerosol and hydrogen gas at the bath surface. | Almost Certain (A) without rim LEV on plating tanks |
| Cadmium dust generation during opening, shredding, or smelting of nickel-cadmium batteries in recycling operations | NiCd batteries contain 15–20% cadmium by weight. | Almost Certain (A) during uncontrolled mechanical processing |
| Skin and eye contact with cadmium compounds during plating solution handling or surface cleaning | Cadmium compounds cause localised skin irritation, dermatitis, and mucous membrane irritation. | Likely (B) during plating solution top-up, filter maintenance, and tank cleaning without appropriate PPE |
| Ingestion of cadmium via contaminated hands, surfaces, food, or drink | Oral ingestion of cadmium results in direct gastrointestinal absorption, contributing to the total body cadmium burden. | Possible (C) without strict hygiene controls and demarcated clean eating areas |
| Disposal and handling of cadmium-contaminated waste including filters, PPE, sludge, and plating residues | Cadmium waste — LEV filters, plating sludge, used PPE, contaminated cleaning cloths — retains its cadmium content and presents ongoing inhalation and contact exposure risk to workers who handle it without appropriate controls. | Likely (B) without a documented waste handling and disposal procedure |
Controls (Hierarchy of Controls)
Recent Prosecutions
A metal recycling operation processed NiCd batteries without adequate LEV or health monitoring. Workers were found to have urinary cadmium levels exceeding the biological action level, indicating significant systemic absorption. The regulator issued improvement notices requiring immediate LEV upgrade, biological monitoring, and cessation of battery processing until controls were verified. The operator had no SWMS and no exposure monitoring programme in place.
2023 — SafeWork NSW enforcement register
Following the announcement of the new 0.001 mg/m³ WEL effective 1 December 2026, Australian state WHS regulators issued advisory notices to the electroplating industry identifying cadmium plating operations as a priority inspection target. Operators without current exposure monitoring data referenced to the new WEL, without biological monitoring programmes, and without SWMS addressing the new limit face Category 1 or 2 prosecution risk if workers are exposed above the revised limit.
2026 — Safe Work Australia WEL transition guidance
What Your SWMS Must Include
Related SWMS
SWMS templates for this work
⛏️Diesel Particulate Matter (DPM) Underground SWMS
Underground diesel-engine exhaust exposure — DPM/elemental carbon at the new 0.05 mg/m³ ceiling under the 1 De…
⚗️Cadmium Work SWMS
Handling, cutting, welding, grinding or heating cadmium-containing materials — galvanised steel welding, cadmi…
🥣Food Mixer Operation SWMS
Commercial dough mixer and planetary food mixer operation in bakery and food processing. Covers bowl-guard int…
New 0.001 mg/m³ WEL from 1 December 2026 — Is Your Cadmium SWMS Compliant?
This template pre-loads cadmium-specific hazards, the new WEL references, LEV specifications, biological monitoring requirements, and IARC Group 1 carcinogen controls. CIH-reviewed, editable DOCX, 8 Australian state variants. $75 AUD.
Get Cadmium Work SWMS — $75 →